“INTELPHONE”
HANDS FREE TELEPHONE SYSTEM IN CASE OF EMERGENCY
INTELPHONEisanelectronicdevicethancancall 4
pre stored numbers, in cases of
emergency, and it is necessary in the installation of elevator.
INTELPHONEisdesignedtofulfill the requirements of
European standard EN 81-28for emergency
systems in elevators.
The device is autonomous and it is power supplied only
from the telephone line (it does not need batteries or any other kind of power)
COMPATIBILITY WITH STANDARD EN
81-28 :
·
Automatic telephone connection with the press of a button
through the cabin. EN81-28 4.1.1/7
·
Ability Function without batteries or any other kind of
power. EN81-28 4.1.3
·
Optical information for the condition of the device inside
the cabin. EN81-28 4.1.4
·
Rejection of unjustified alarm. EN81-28 4.1.5
·
Forwarding the identity of the device with DTMF tones
through the telephone line. EN81-28 4.1.6
·
Ability of rejecting-terminating the communication. EN81-28 4.1.7
BRIEF OPERATION DESCRIPTION
·
Automatic communication with the press of a button.
·
Automatic call function through control command.
·
External call acceptance.
·
Identification of ‘busy’ or ‘no answer’ and automatic call
of the next number.
·
Volume adjustment of the speaker.
·
Input for the filter from any electronic device (for
example control panel)
·
Automatic adjustment on an ISDN center.
·
Forwarding the identity of the device with DTMF tones.
EXPLANATIONS
·
‘LINE’ terminal: We connect the telephone
line.
·
‘BUTTON’ terminal: It is used for the function of
the device and we connect the button ‘Emergency Bell’.
·
‘SPEED’
trimmer: We adjust the priority
between earphone and microphone.
·
‘CONTROL’ terminal: Input command
from any electronic device (control panel) to start the dialing procedure.
·
'INPUT' terminal: Filter input from any
electronic device.
·
Picto1,2 terminal: Output connections for
pictographs(when it is necessary) [full version].
·
- + terminal: Power supply of pictographs,
self-test circuit and relay contacts NC C NO [full version].
·
NC C NO terminal:
Relay contacts. They are used for giving commands to any electronic device
[full version].
OPERATION DESCRIPTION
AUTOMATIC COMMUNICATION WITH THE PRESS OF A BUTTON
FROM THE CAR.
This is the main function of
‘INTEL PHONE’. If we press the appropriate key on the operation panel of the car
(usually identified as ‘Emergency Bell’), dialing automatically starts with the
first of the four numbers which are stored in the INTEL PHONE. For storing the
four numbers, (see § “Programming”)
The emergency key should be pressed until the yellow led is on and we
hear the dial tone. That needs approximately 4 seconds (If the emergency key is
pressed accidentally, action is ignored).
Then the device is automatically dialing the emergency number that is
stored in place 1 (S1). If the number is ‘busy’ or ‘no answer’ then the device
starts dialing the next stored number.
Three attempts are made
sequentially with numbers S1, S2, S3 and S4. If all 12 attempts fail then the
device will be shut down and we must repeat the starting procedure from the
beginning.
The sequence of choices is
: <S1,S2,S3,S4,S1,S2,S3,S4,S1,S2,S3,S4>
AUTOMATIC CALL OPERATION THROUGH
CONTROL COMMAND
Exactly the same procedure as described above could also be done with the
way below:
The control system of the elevator (or some other electronic system)
could start the same automatic dialing just as described above by placing
voltage 12V in the contacts CONTROL of the device.
Through the sort-circuit NO / NC
we choose the appropriate operation as needed each time.
Α)In ΝΟ place, start is accomplished if we give voltage 12V
in the terminal CONTROL.
Β)In NC place, start is accomplished if we disconnect voltage 12V from the terminal CONTROL.
ACCEPTANCE OF EXTERNAL CALLS
With INTEL PHONE we can accept external calls from
other telephones. The device answers to the call if we wish, after a specified
number of rings (see § “Programming”)and remains ‘on the line’ for 6 minutes.
IMPORTANT NOTICE
INTEL PHONE does not give an acoustic signal for
incoming calls. That means that the trapped people do not observe the external
connection with the INTEL PHONE. To start the communication someone should
first speak to them.
PROGRAMMING
There should
be a connection with the telephone in order to start programming. The
programming procedure is interrupted when the connection is terminated.
Before any
kind of programming INTEL PHONE must be turned on. That happens if we press the
program key ‘PR’ placed on the keyboard. We can hear on the earphone the line
signal (yellow led on).
If we have
stored a lock access code, we must enter it, in order to continue with
programming.
This code is
not necessary if we do not store it (#89 adjustment or 0000 as a code)
With every
acceptable command INTEL PHONE informs the user with 2 ‘bip’ (O.K.)
After every adjustment
INTEL PHONE remains on and waits for a new command.
With PR key we
can turn off /on the device at any time, only during programming.
STORING TELEPHONE NUMBERS
If we do not have an acoustic signal in the earphone, we
must press ‘PR’ key and enter the access code (if needed) .
(Ο.Κ.) =’bip’ from the device.
1st Telephone number : S+1(O.K.)<
‘telephone number’>S(O.K.)
2nd Telephone number: S+2(O.K.)<
‘telephone number’>S(O.K.)
3rd Telephone number: S+3(O.K.) < ‘telephone
number’>S(O.K.)
4th Telephone number: S+4(O.K.)< ‘telephone
number’ >S(O.K.)
With this way
the necessary telephone numbers are stored in the internal memory of INTEL
PHONE (S1, S2, S3 and S4)
In case of wrong handling, shut down the telephone,
by pressing the 'PR' key wait for three seconds and then press the ‘PR” key
again to restart the programming procedure.
All 4 memory positions must ALWAYS be occupied with a telephone number.
If only one number is available, then it should be written in all four
positions.
SPECIAL FUNCTIONS
The
device must be turned on first, by pressing the
‘PR’ key.
#080
: Adjusting earphone volume
Press 1 to increase volume. Press 2 to decrease volume.
After the desirable adjustment, press * for storing. Factory preset <50%>.
#081n
: Number of rings for answering when someone is calling
n = a number from 0 to 9
This number stands for how many times the device will be ringing
before it answers.
By placing number 0 the device does not answer. Factory preset < 0 >.
After the desirable choice, the device will send an
‘ok’ signal
#082
: Adjusting the ‘ISDN’ –for intracom’s modem(deactivate
the 'on hook' delay)
INTEL PHONE starts and
automatically calls code **71# to cancel the 'on hook' delay.
The
device will send an ‘ok’ signal after 1 second.
#083
: Adjusting the ‘ISDN’–for intracom’s modem (accepting ‘flash’ time)
INTEL PHONE starts and automatically calls code **25*20#, to adjust ‘flash’ time less
than 200 msec.
The device will send
an ‘ok’ signal after 1 second.
Terminating the call during communication (when green
light is on).
#084*
user has the ability to terminate the call during
communication (green light on), if the button is pressed for more than 3 seconds.
If pressed for less than three seconds the INTEL PHONE calls the next number.
#084#
choice is deactivated. Factory preset
< deactivated function>.
After the desirable choice, the device
will send an ‘ok’ signal.
Option
of accepting filter function.
#085* activate filter (lift in working
condition)
#085# choice is deactivated. Factory preset < deactivated function>.
After the desirable choice, the device
will send an ‘ok’ signal.
Option of automatic sending the ID of the INTEL
PHONE.
#086* activates INTEL
PHONE to automatically send the ID when it comes to speaking condition or when
it answers when it is called.
#086# choice is deactivated. Factory preset < deactivated>.
After the desirable choice, the device will send
an ‘ok’ signal.
#87n: Number of days for self test. (FULL VERSION
ONLY)
(There must be a power supply of 12V in terminals + - in
order to use this application)
We enter a number from 0 to 9 (for n= 0 to 9)
This number indicates the number of days after which the
device will give the code to make a self test.
When the chosen number is 0 then the device does not make a
self test
Factory preset<3>.
After the desirable choice, the device will send an ‘ok’ signal.
Enter
the identification number of INTEL PHONE. (n=number)
#088nnnn
nnnn = 4 numbers of
identification code.
When the rescue service receives these numbers then knows the exact details of the installation.
Factory
preset < 0000>.After the
desirable choice, the device will send an ‘ok’ signal.
Changing
the lock access code to the functions of the INTEL PHONE.
#089nnnn
nnnn = 4 numbers, that will
represent the lock access code, to the
functions of the INTEL PHONE.
When the code is 0000 it is not requested in the
beginning.
Factory preset < 0000 >.no lock access code
After the desirable choice, the device
will send an ‘ok’ signal.
Option of pulse or tone system.
#090*
pulse system
#090# tone system. Factory preset <tone system>
#091n
: Numbers of seconds between 1st and 2nd digit of calling
number
n = a number from 1 to 9.
This number indicates the number of seconds between 1st and 2nd
digit of the calling number
Factory preset<1>.
#092n
: Numbers of calling times to next number
n = a number from 1 to 9.This
number indicates the number of calling times before calling the next number
Factory preset<6>.
Option
for connecting Intelphone INTD0900 with GSM INTD0909
#093* activates the option.
#093# deactivates the option.
Before you go through another adjustment, you have to wait
for 2 bips from intelphone.
Factory preset < deactivated >.
This option is ready only for Intelphones that
have serial number from S/N5326i and above.
#08i
: Restoring factory adjustments.
It restores the factory adjustments and deletes the 4
stored numbers of lock access code and ID
After the desirable choice, the device
will send an ‘ok’ signal.
COMPLIANCE TO EC DIRECTIVES
The Directive
99/5/EC describes that “At the choice of the manufacturer, compliance of the
apparatus with the essential requirements identified in Article 3(1)(a) and (b)
may be demonstrated using the procedures specified in Directive 73/23/EEC and
Directive 89/336/EEC respectively, where the apparatus is within the scope of
those Directives, as an alternative to the procedures laid out below.”
Telecommunications terminal equipment which does not
make use of the spectrum allocated to terrestrial/space radio communication and
receiving parts of radio equipment shall be subject to the procedures described
in any one of Annexes II, IV or V at the choice of the manufacturer.
Relevant harmonized standards
For
EMC (Directive 89/336/EEC)
Emission
|
EN 55022
|
Immunity
|
EN 55024
|
ESD
|
EN 61000-4-2
|
Injected Current
|
EN 61000-4-6
|
Magnetic
field
|
EN 61000-4-8
|
Continuous
radiated disturbances
|
EN 61000-4-3
|
Surges
|
EN 61000-4-5
|
Fast transient
|
EN 61000-4-4
|
Radiated Emission
|
EN 55022
|
For
safety ( Directive73/23/EEC)
EN 60950 §
2.1.4,2.2.3,6.1,6.2,6.2.1,6.2.1.1,6.3.1,6.3.2
For performance
TBR 21 § 4.4.1, 4.4.2.2, .3, 4.4.3, 4.4.4, 4.5, 4.6, 4.6.2, 4.7.1, 4.7.2,
4.7.3.1, 4.7.3.2, 4.7.3.3, 4.7.3.4.1, 4.7.3.4.2, 4.7.4.1, 4.7.5, 4.8.1.1, 4.8.1.2,
4.8.2.1, 4.8.2.2.1, 4.8.2.2.2, 4.8.2.4, 4.8.2.5, 4.8.3, 4.9.
Fordirective
EN
81-28
4.1.1
Alarms
Compliance
4.1.2
End of alarm Compliance
4.1.3
Emergency
electrical power supply
Compliance
4.1.4
Information in
the lift car
Compliance
4.1.5
Alarm filtering *
4.1.6
Identification **
4.1.7
Communication Compliance
4.2.1
Availability Compliance
*
Through the relay in the control panel
** Through call ID or
INTD0101 device (A system that we manufacture. It takes the information from
the INTEL PHONE and transfers them
to a computer)
|
DECLARATION OF CONFORMITY
·
ΔΗΛΩΣΗΣΥΜΜΟΡΦΩΣΗΣ
|
Manufacturer’sName
Όνομα κατασκευαστή
|
E. PELEKIS and
Co
E. ΠΕΛΕΚΗΣ και ΣΙΑ OE
|
Manufacturer’sAddress Διεύθυνση Κατασκευαστή
|
Hr. Karvouni 27- AHARNAI
Χρ. Καρβούνη 27 – ΑΧΑΡΝΑΙ
|
Declares
that the product: Emergency Lift Telephone
Δηλώνει, ότι το προϊόν: Τηλέφωνο ανάγκης για Ανελκυστήρα
Product Name: “INTELPHONE”
Ονομασία: “INTELPHONE”
 Model Number(s): INTELCO 6001
Product Number(s) / Κωδικοί Προϊόντος:
|
Conforms with the essential requirements of
the Radio & Telecommunications
Terminal Equipment directive 1999/5/EC and satisfies all the
applicable standards to the product within this directive as follows:
Συμμορφώνεται με τις ουσιώδεις
απαιτήσεις της κοινοτικής οδηγίας
Ραδιοεξοπλισμού & Τηλεπικοινωνιακού Τερματικού Εξοπλισμού 1999/5/ΕK (ΦΕΚ 44/Α/7-3-2002) και ικανοποιεί
όλα τα πρότυπα της κοινοτικής οδηγίας που εφαρμόζονται για το προϊόν όπως
αυτά αναφέρονται παρακάτω:
article
3.1a / άρθρο
3.1α:
PERFORMED/ΕΦΑΡΜΟΣΤΗΚΕ
article
3.1b / άρθρο
3.1β:
PERFORMED/ ΕΦΑΡΜΟΣΤΗΚΕ
Date and location/Τόπος, Ημερομηνία
ATHENS 2/11/2004
Signature
/Υπογραφή
·
|
|
|
|
|